Efficient Energy Solutions

Air Source Heat Pump

Air source heat pump technology extracts heat from the air and uses a small amount of electricity to generate efficient thermal energy for heating, hot water supply, drying, and other applications.

Airsource Heat Pump Unit
Product Series
  • commercial ambient temperature air source heat pump (chilled water) unit.
  • Low temperature air source heat pump water heater unit.
  • Low temperature air source heat pump (chilled water) unit.
  • Variable frequency low temperature air source heat pump (chilled water) unit.
Application Areas
  • Homes, residences, villas, guesthouses, hospitals, schools, office buildings.
  • Public institutions, factories, banks, bath centers, clubs, hotels, resorts.
  • Airport waiting halls, medium- to large-scale central heating systems, mixed-use developments, and more.

Performance Characteristics

Performance Characteristics
Solve Both Heating and Cooling Needs in One Step for Ultimate Comfort
  • Solve heating and cooling needs in one step for ultimate comfort.
  • Achieve whole-house heating in winter and central air conditioning in summer.
  • Enjoy a comfortable life with stable temperatures all year round.
High Heat Pump System becomes Smart Anti Free e1783931304188

An air source heat pump unit consists of an outdoor air-source air conditioning unit, indoor underfloor heating, fan coil units, and an intelligent control system. During winter operation, the air source heat pump collects heat from the outdoor air, heats the water in the underfloor heating pipes, and then supplies the hot water required for heating. This hot water is pumped into the indoor low-temperature environment for even heating, gradually raising the temperature to achieve the desired warmth. In summer, a water-based central air conditioning system is used for ventilation and cooling.

Because heat pump heating does not involve combustion, it is an environmentally friendly technology. Compared with direct electric underfloor heating, its COP is greater than 3, resulting in significant energy savings.

Smart Control
  • Uses microcomputer intelligent control technology.
  • Fully automatic operation.
  • No specialized maintenance is required, making it easier to use.
Widely Adaptable to All Kinds of Weather
  • Can operate in sunny, rainy, snowy, or cloudy conditions as long as air is available.
  • Uses ultra-low temperature technology.
  • Handles cold northern winters with ease.
Energy-Saving and Efficient
  • Absorbs and converts a large amount of energy from the air.
  • Provides up to 75% energy savings compared with traditional methods.
Eco-Friendly
  • Uses environmentally friendly refrigerants and does not involve combustion.
  • No exhaust gas or waste residue emissions.
Flexible Installation
  • Can be installed on the ground or roof.
  • No equipment room is required, saving installation space.
Long Lifespan
  • Designed for a service life of up to 25 years.
  • Low operating costs.

Premium Parts

Premium Parts
Finned Heat Exchanger
20260713 164347
Finned Heat Exchanger
  • The unit’s air source heat exchanger uses a high-efficiency copper tube and aluminum finned coil heat exchanger, ensuring smoother airflow, reducing frost formation, and improving heat exchange performance.
  • The heat exchanger uses internally threaded tubes, which not only increase the heat exchange area but also enhance refrigerant turbulence for better heat transfer efficiency.
Dedicated Compressor
Dedicated Compressor
  • Dedicated compressor for heat pumps.
  • Suitable for the high-pressure and high-temperature operating conditions of heat pumps.
  • Provides stable and reliable operation with low vibration, ensuring a longer service life.
Four-Way Valve
Four-Way Valve
  • Dedicated four-way valve for inlet.
  • Equipped with a unique device to prevent short cycling.
  • Suitable for rapid switching when the pressure difference between the high and low sides is very small.
  • Helps minimize pressure loss and valve leakage.
Bi-Directional Liquid Storage Tank
Bi-Directional Liquid Storage Tank
  • Durable and long-lasting with improved heat exchange performance.
  • More energy-efficient.
Thermal Expansion Valve
Thermal Expansion Valve
  • Special thermal expansion valve for import.
  • High material hardness and long-lasting durability.
  • High efficiency and smooth operation.
  • Suitable for various operating conditions.
Plate Heat Exchanger
Plate Heat Exchanger
  • Uses airfoil-shaped, long-chord serrated patented blades. The fan features low noise, low overall heat generation, and energy-saving operation.
  • Long service life.
  • The fan’s energy efficiency reaches Level 1.
Gas-Liquid Separator
Gas-Liquid Separator
  • High separation efficiency with low vibration and low noise.
  • Energy-saving with high thermal efficiency.
  • Compared with traditional heat exchange systems, thermal efficiency reaches 100%, saving more than 20% steam.
Plate Heat Exchanger
Plate Heat Exchanger
  • European design with high heat transfer efficiency.
  • High temperature and pressure resistance with leak-free operation.
  • Efficient technology with a high heat transfer coefficient.
  • Long service life.
Motor
Motor
  • High-efficiency, long-lasting motor
  • Effectively reduces losses in electromagnetic energy, thermal energy, and mechanical energy.
  • Improves operational efficiency while maintaining low noise levels.

Technical Principle

Technical Principle
2026 07 13 165957 515

Based on the reverse Carnot cycle principle, this system mainly consists of two parts: the air source heat pump unit and the terminal units. The air source heat pump unit and the terminal units work together; the former provides chilled or hot water, while the latter provides cooling or heating through heat exchange. The air source heat pump unit is the main unit of the heating system. Because it uses an air source condenser, no cooling tower is required; the evaporator is water-cooled, providing chilled water in summer and hot water in winter. The fan coil unit is the terminal device of the air conditioning system and is installed indoors. Just as a water pump lifts water from a low point to a high point, a heat pump can transfer heat from a low-temperature source to a high-temperature environment. Therefore, a heat pump is essentially a heat transfer device; its function is to extract heat from the surrounding environment and transfer it to the object being heated (a higher-temperature object).

Energy Saving Comparison

Comparison of Air Source Heat Pumps with Other Heating Methods

CategoryBlue Lake Air Source Heat Pump (Central AC + Heating)Coal Boiler Central HeatingSmall Boiler (Community Central Heating)Gas Wall‑Mounted Boiler (Individual Heating)Electric Floor Heating (Individual Heating)
Energy SavingCompared with traditional electric heating, saves 75% energyCoal heating, not energy‑efficient, high pipeline heat lossCoal heating, not energy‑efficientGas heating, not energy‑efficientElectric heating, not energy‑efficient
Operating CostVery lowMediumHighMediumHigh
Environmental ProtectionZero emissions, very environmentally friendlyExhaust emissions, heavy pollutionExhaust emissions, heavy pollutionExhaust emissions, heavy pollutionRadiation present
SafetyNo combustion; water and electricity separated; very safeRisk of combustion and explosionRisk of combustion and explosionRisk of combustion and explosionElectrical safety risks
ApplicabilityUsers can freely adjust heating time and temperatureLimited by centralized heating scheduleUsers cannot adjust independentlyUsers can adjust independentlyLimited by household electrical capacity
Maintenance CostNo dedicated maintenance requiredRequires professional maintenanceRequires regular professional inspectionRequires regular professional inspectionRequires regular professional inspection

Comparison of Operating Costs of Heating Methods

Normal Winter
ItemUnitBlue Lake Air Source Heat PumpCoal BoilerNatural Gas BoilerOil BoilerElectric Boiler
Heating Equipment/Heat PumpBoilerBoilerBoilerBoiler
Energy Type/ElectricityCoalNatural GasDieselElectricity
Calorific Valuekcal (m³)860500086009600860
Heating Efficiency / Heat Transfer Efficiency/3.60.50.80.80.9
Heating Area130130130130130
Unit Heat IndexW/m²120120120120120
Air Conditioning Heat LoadkW1616161616
Daily Heating Timeh1010101010
Fuel / Energy PriceCNY / kWh (m³)0.60.62.670.6
Daily Heating CostCNY / day23294611094
Operating Daysdays120120120120100
Total Seasonal Operating CostCNY280834775476132069360