Airsource Heat Pump Unit

Central Air Conditioning for Heating and Cooling

Air source heat pump heating technology extracts heat from the air, uses a small amount of electricity to drive internal operations, and produces efficient heat energy for heating, hot water drying, and other purposes.

Airsource Heat Pump Unit
Product Series
  • Commercial ambient temperature air source heat pump (chilled water) unit
  • Low temperature air source heat pump water heater unit
  • Low temperature air source heat pump (chilled water) unit
  • Variable frequency low temperature air source heat pump (chilled water) unit
Application Areas
  • Homes, residences, villas, guesthouses, hospitals, schools, office buildings
  • Public institutions, factories, banks, bath centers, clubs, hotels, resorts
  • Airport waiting halls, medium to large-sized central heating systems, mixed-use developments, etc.

Performance Characteristics

Performance Characteristics
Solve Both Heating and Cooling Needs in One Step for Ultimate Comfort
  • Solve both heating and cooling needs in one step for ultimate comfort
  • Achieve whole-house heating in winter and central air conditioning in summer
  • Enjoy a comfortable life with constant temperature all year round
High Heat Pump System becomes Smart Anti Free e1783931304188

An air source heat pump unit consists of an outdoor air-source air conditioning unit, indoor underfloor heating, fan coil units, and an intelligent control system. During winter operation, the air source heat pump collects heat from the outdoor air, heats the chilled water in the underfloor heating pipes, and then supplies the hot water needed for heating. This hot water is then pumped into the indoor low-temperature environment for even heating, gradually raising the temperature to achieve the desired warmth. In summer, a water-based central air conditioning system is used for ventilation and cooling.

Because heat pump heating does not involve combustion, it is an environmentally friendly technology. Compared to direct electric underfloor heating, its COP is greater than 3, resulting in significant energy savings.

Smart Control
  • Uses microcomputer intelligent control
  • Fully automatic operation
  • No need for specialized maintenance, making it easier to use
Widely Adaptable to All Kinds of Weather
  • It can run in sun, rain, snow, or clouds as long as there’s air
  • Uses ultra-low temperature technology
  • Handles cold northern winters
Energy-Saving and Efficient
  • Absorbs and converts a large amount of energy from the air
  • Up to 75% more energy-saving than traditional methods
Eco-Friendly
  • Uses eco-friendly refrigerant, doesn’t burn
  • No exhaust gas or waste residue emissions
Flexible Installation
  • Can be installed on the ground or roof
  • No equipment room needed, takes up little space
Long Lifespan
  • Designed to last up to 25 years
  • Low operating costs

Premium Parts

Premium Parts
Finned Heat Exchanger
20260713 164347
Finned Heat Exchanger
  • The unit’s air source heat exchanger uses a high-efficiency copper tube and aluminum finned coil heat exchanger, which makes airflow smoother, reduces frost formation, and improves heat exchange capacity.
  • The heat exchanger uses internally threaded tubes, which not only increases the heat exchange area but also enhances the refrigerant’s turbulence performance.
Dedicated Compressor
Dedicated Compressor
  • Dedicated compressor for heat pumps
  • Suitable for the high-pressure and high-temperature conditions of heat pumps
  • Stable and reliable operation, low vibration ensures a longer service life
Four-Way Valve
Four-Way Valve
  • Dedicated four-way valve for inlet
  • Equipped with a unique device to prevent short cycles
  • Suitable for instant switching when the pressure difference between high and low sides is very small
  • Can minimize pressure loss and valve leakage
Bi-Directional Liquid Storage Tank
Bi-Directional Liquid Storage Tank
  • Durable and long-lasting, with better heat exchange
  • More energy-efficient
Thermal Expansion Valve
Thermal Expansion Valve
  • Special thermal expansion valve for import
  • High material hardness, long-lasting durability
  • High efficiency, smooth operation
  • Suitable for various working conditions
Plate Heat Exchanger
Plate Heat Exchanger
  • Uses airfoil-shaped, long-chord serrated patented blades. The fan has low noise, low overall heat generation, and is energy-saving
  • Long service life
  • The fan’s energy efficiency reaches Level 1
Gas-Liquid Separator
Gas-Liquid Separator
  • High separation efficiency, low vibration, low noise
  • Energy-saving, high thermal efficiency
  • Compared with traditional heat exchange systems, thermal efficiency reaches 100%, saving more than 20% steam
Plate Heat Exchanger
Plate Heat Exchanger
  • European design, high heat transfer efficiency
  • High temperature and pressure resistance, no leaks
  • Efficient technology, high heat transfer coefficient
  • Long service life
Motor
Motor
  • High-efficiency, long-lasting motor
  • Can effectively reduce losses in electromagnetic energy, thermal energy, and mechanical energy
  • Improves operational efficiency and has low noise

Technical Principle

Technical Principle
2026 07 13 165957 515

Based on the reverse Carnot cycle principle, this system mainly consists of two parts: the air source heat pump unit and the terminal units. The air source heat pump unit and the terminal units work together; the former provides chilled or hot water, while the latter, through heat exchange, provides cooling or heating. The air source heat pump unit is the main unit in the heating system. Because it uses an air source condenser, a cooling tower is not required; the evaporator is water-cooled, providing chilled water in summer and hot water in winter. The fan coil unit is the terminal device of the air conditioning system, installed indoors. Just as a water pump lifts water from a low point to a high point, a heat pump can extract heat from a low temperature to a high temperature. Therefore, a heat pump is essentially a heat lifting device; its function is to extract heat from the surrounding environment and transfer it to the object being heated (a higher-temperature object).

Energy Saving Comparison

Comparison of Air Source Heat Pumps with Other Heating Methods

CategoryBlue Lake Air Source Heat Pump (Central AC + Heating)Coal Boiler Central HeatingSmall Boiler (Community Central Heating)Gas Wall‑Mounted Boiler (Individual Heating)Electric Floor Heating (Individual Heating)
Energy SavingCompared with traditional electric heating, saves 75% energyCoal heating, not energy‑efficient, high pipeline heat lossCoal heating, not energy‑efficientGas heating, not energy‑efficientElectric heating, not energy‑efficient
Operating CostVery lowMediumHighMediumHigh
Environmental ProtectionZero emissions, very environmentally friendlyExhaust emissions, heavy pollutionExhaust emissions, heavy pollutionExhaust emissions, heavy pollutionRadiation present
SafetyNo combustion; water and electricity separated; very safeRisk of combustion and explosionRisk of combustion and explosionRisk of combustion and explosionElectrical safety risks
ApplicabilityUsers can freely adjust heating time and temperatureLimited by centralized heating scheduleUsers cannot adjust independentlyUsers can adjust independentlyLimited by household electrical capacity
Maintenance CostNo dedicated maintenance requiredRequires professional maintenanceRequires regular professional inspectionRequires regular professional inspectionRequires regular professional inspection

Comparison of Operating Costs of Heating Methods

Normal Winter
ItemUnitBlue Lake Air Source Heat PumpCoal BoilerNatural Gas BoilerOil BoilerElectric Boiler
Heating Equipment/Heat PumpBoilerBoilerBoilerBoiler
Energy Type/ElectricityCoalNatural GasDieselElectricity
Calorific Valuekcal (m³)860500086009600860
Heating Efficiency / Heat Transfer Efficiency/3.60.50.80.80.9
Heating Area130130130130130
Unit Heat IndexW/m²120120120120120
Air Conditioning Heat LoadkW1616161616
Daily Heating Timeh1010101010
Fuel / Energy PriceCNY / kWh (m³)0.60.62.670.6
Daily Heating CostCNY / day23294611094
Operating Daysdays120120120120100
Total Seasonal Operating CostCNY280834775476132069360